Shopping cart is empty.

Intercon 237 Restroom and Shower Cleaner 1 Gallon


 

Intercon 237 Restroom and Shower Cleaner 1 Gallon

Price $33.82

  • Quantity
CHM-WH-IC-237 #01857;4pcs(@1gallon)/case;Case;
2







_x000D_ _x000D_ _x000D_ _x000D_ _x000D_ _x000D_ _x000D_ _x000D_ _x000D_
_x000D_
_x000D_

_x000D_ Intercon - Tile Brite product is a one-step disinfectant cleaner with mild phosphoric acid and chelating agents that attack soap scum and hard water deposits in restrooms, showers, kitchens and other areas. This product is also effective for mold and mildew control, as well as being effective in both hard water and organic soil tolerance._x000D_

_x000D_
_x000D_

Product dimensions:
_x000D_ -_x000D_

Product weight:
_x000D_ 10 lbs. Each_x000D_

_x000D_
_x000D_

  • _x000D_ Product Properties
  • COLOR Translucent Blue
  • ODoR Sassafras
  • VISCOSITY 10 cps
  • pH 0.7
  • FLASH POINT None
  • SPECIFIC GRAVITY 1.05
  • DETERGENCY Excellent
  • SOLUBILITY IN WATER Complete
  • ACTIVE AGENT Quaternary Ammonium Chlorides_x000D_

_x000D_
_x000D_

Usage Tips:
_x000D_ PREPARATION OF DISINFECTANT USE-SOLUTION: Add 3 Oz. per gallon of water [for 250 ppm water hardness] Add 4 Oz. per _x000D_ gallon of water [for 400 ppm water hardness]._x000D_ DISINFECTION DIRECTIONS: Apply use-solution with a cloth, mop, sponge, or sprayer or by soaking until surfaces are thoroughly _x000D_ wet. Treated surfaces must remain wet for 10 minutes. Wipe dry with a clean cloth or sponge or let air dry. For sprayer applications, _x000D_ use a coarse spray device. Spray with quick full strokes 6 - 8 inches from surface. Rub with a brush, sponge or cloth. Do not _x000D_ breathe spray. After use, close nOzzle. For heavily soiled areas, a preliminary cleaning is required. Prepare a fresh solution daily or _x000D_ more often if use solution becomes diluted or soiled. Rinse all surfaces that come in contact with food such as countertops, _x000D_ appliances, tables and stovetops with potable water before reuse. This product must not be used to clean utensils, glassware and _x000D_ dishes._x000D_ VIRUCIDAL DIRECTIONS: Follow Disinfection Directions. Treated surfaces must remain wet for 1 minute. Allow surfaces to air dry._x000D_ MOLD AND MILDEW CONTROL DIRECTIONS: Add 3-4 Oz. per gallon of water, to inhibit the growth of mold and mildew and _x000D_ their odors on hard, nonporous surfaces. Thoroughly wet all treated surfaces completely. Let air dry. Repeat application weekly or _x000D_ when growth or odor reappears._x000D_ TOILET BOWL/URINAL DISINFECTANT AND CLEANER DIRECTIONS: Remove gross filth before disinfection. _x000D_ From concentrate: Add [3-4 Oz.] to the toilet bowl or urinal and mix. Thoroughly brush or swab over exposed surfaces and under _x000D_ the rim with a cloth, mop, brush or sponge. Allow to stand for 10 minutes and flush. _x000D_ From use-solution: Empty toilet bowl or urinal and apply a 3-4 Oz. per gallon use solution to exposed surfaces including under _x000D_ the rim with a cloth, mop, sponge or sprayer, allow to stand for 10 minutes and flush._x000D_ TO CLEAN AND DEODoRIZE: Use from 1:10 dilution up to full strength. Apply product to wet the surface thoroughly. Let stand _x000D_ for at least one minute, rinse with water or allow to air dry. For cleaning and deodorizing shower stalls and shower fixtures: starting _x000D_ at the bottom and working toward the top, apply to the surface and spread with a brush, sponge or cloth. Let Set for a minute, _x000D_ agitate to loosen stubborn accumulations and then rinse with water. _x000D_ KILLS HIV-1 ON PRECLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in _x000D_ health care Settings or other Settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood _x000D_ or body fluids and in which the surfaces/objects likely to be soiled with blood or body fluids can be associated with the potential _x000D_ for transmission of Human Immunodeficiency Virus Type 1 [HIV-1] [associated with AIDS]._x000D_ Special Instructions for Cleaning and Decontamination against HIV-1 on Surfaces/ Objects Soiled With Blood/Body Fluids._x000D_ Personal Protection: Clean-up must always be Done wearing protective gloves, gowns, masks and eye protection. _x000D_ Cleaning Procedure: Blood and other body fluids containing HIV must be thoroughly cleaned from surfaces and objects before _x000D_ application of this product. _x000D_ Contact Time: Leave surface wet for 1 minute. Use a 10-minute contact time for disinfection against all other bacteria claimed. _x000D_ Disposal of Infectious Materials: Blood, body fluids, cleaning materials and clothing must be autoclaved and disposed of _x000D_ according to local regulations for infectious waste disposal._x000D_

Additional info:
_x000D_ KEEP OUT OF REach OF CHILDREN_x000D_ DANGER. Corrosive. Causes irreversible eye damage and skin burns. Do not get in eyes, on skin or on clothing. Wear protective _x000D_ eyewear (goggles, safety glasses or face shield), protective clothing and protective gloves (rubber or chemical resistant) when _x000D_ handling. Do not breathe spray. May be fatal if swallowed. Avoid contamination of food. Wash thoroughly with soap and water _x000D_ after handling and before eating,drinking, using tobacco, chewing gum or using the toilet. Remove contaminated clothing and _x000D_ wash clothing before reuse._x000D_ _x000D_

_x000D_
_x000D_
_x000D_

_x000D_ CHM-WH-IC-237 #01857_x000D_